• 39 Douglas Crescent. Randburg, Gauteng
  • 079 232 8681
  • contact@arccenter.co.za
Emergency Support Chat: (063) 617 6968
Daikin Electrical Appliances

Daikin Appliances
Repairs & Service Centre

Recognized for their innovation in climate control technology, providing high-efficiency solutions
Split-System Air Conditioners. Air Purifiers. Heat Pumps. Smart Thermostats. VRV/VRF Systems

Daikin Industries Ltd.,  was founded in 1924 in Osaka, Japan. it has since grown to become is a global leader in air conditioning, heating, ventilation, and refrigeration (HVAC) solutions. Over the past century, Daikin has been at the forefront of technological advancements in climate control systems. The company developed the first air conditioner using a non-flammable refrigerant, and it is widely known for its commitment to energy efficiency and environmentally friendly practices.

Daikin Air Conditioner

Daikin is recognized for its innovation in inverter technology and VRV (Variable Refrigerant Volume) systems, revolutionizing the HVAC industry. Today, Daikin operates globally, offering high-quality air conditioning systems for residential, commercial, and industrial applications.

Popular Daikin Appliances

Daikin Home Appliances

  • Split-System Air Conditioners (Cooling/Heating)
  • Multi-Split Air Conditioners
  • Air Purifiers
  • Heat Pumps
  • Smart Thermostats

Daikin Commercial Appliances:

  • VRV/VRF Systems (Variable Refrigerant Volume/Flow)
  • Packaged Rooftop Units
  • Commercial Air Conditioning Systems (Split, Multi-Split)
  • Commercial Refrigeration Systems
  • Chillers (Air-Cooled, Water-Cooled)
  • Air Handling Units (AHUs)
  • Commercial Heat Pumps
  • Large-scale HVAC Systems for industrial buildings, offices, and malls
  • Smart Building Automation and Energy Management Solutions

Common Faults and Problems 

Split-System Air Conditioners

  • Refrigerant Leaks: Daikin air conditioners, like other brands, can develop refrigerant leaks over time, which reduces the unit’s ability to cool efficiently. Leaks may occur due to poor installation or wear and tear in the refrigerant lines.
  • Compressor Failures: Over time, the compressor—the heart of the cooling system—may fail due to electrical issues, overuse, or lack of regular maintenance, resulting in the unit not cooling or heating effectively.
  • Clogged Air Filters: Dirty or clogged air filters can reduce airflow and force the air conditioner to work harder, reducing its efficiency and increasing energy consumption.
  • Sensor Malfunctions: In some models, temperature sensors can malfunction, causing the system to either overcool or undercool a room. A sensor may become dislodged or faulty, leading to temperature inconsistencies.

Air Purifiers

  • Filter Blockages: One common issue with Daikin air purifiers is the clogging of filters due to the accumulation of dust, pollutants, and allergens. Regular filter replacements or cleaning are necessary to maintain efficiency.
  • Fan Motor Issues: Over time, the fan motor inside air purifiers may become noisy or stop working altogether due to mechanical wear or blockages from debris.
  • Airflow Problems: Some users experience reduced airflow or uneven distribution of purified air, often caused by a blocked intake or an improperly seated filter.

Heat Pumps

  • Inefficient Heating/Cooling: Daikin heat pumps can develop issues where the heating or cooling output is not adequate, which could be due to thermostat problems, refrigerant leaks, or blockages in the system.
  • Defrost Cycle Failures: Heat pumps in colder climates may develop frost on the outdoor coil. If the defrost cycle is malfunctioning, it may cause the system to struggle with heating, affecting overall performance.
  • Compressor Overheating: Heat pumps sometimes suffer from overheating compressors, often caused by insufficient refrigerant, faulty pressure controls, or airflow restrictions.

Commercial Appliances Common Faults

VRV/VRF Systems

  • Refrigerant Management Issues: VRV and VRF systems are complex and rely heavily on proper refrigerant management. Incorrect refrigerant levels can lead to poor cooling, higher energy consumption, and even system failure. Leaks in these systems can also lead to significant performance drops.
  • Control System Failures: Commercial Daikin systems are equipped with advanced control units to manage multiple zones. A failure in the control system can result in temperature inconsistencies or the inability to properly adjust settings.
  • Fan Motor Burnout: In larger systems, fan motors are more prone to burnout due to continuous use in commercial environments. This can cause inadequate airflow and cooling inefficiency in large spaces.

Packaged Rooftop Units

  • Compressor Failures: These units, used in commercial spaces, often experience compressor issues due to overheating or electrical faults, leading to a loss of cooling or heating capability.
  • Airflow Problems: Blockages or obstructions in ductwork can reduce airflow, causing uneven cooling or heating across large spaces, which is critical in commercial applications.
  • Condenser Coil Damage: Exposure to outdoor elements can cause damage to condenser coils, leading to reduced efficiency and costly repairs if not cleaned or maintained regularly.

Commercial Refrigeration Systems

  • Temperature Regulation Problems: In commercial refrigeration, maintaining a consistent temperature is vital. Issues with thermostats, sensors, or refrigerant levels can lead to inefficient cooling or freezing, potentially spoiling products.
  • Evaporator Coil Icing: Icing on evaporator coils in refrigeration units can occur due to improper defrost cycles or poor airflow, resulting in reduced cooling performance.
  • Compressor Issues: Like in HVAC systems, commercial refrigeration units also face compressor failures due to overuse or lack of regular servicing.

Chillers (Air-Cooled, Water-Cooled)

  • Water Flow Blockages: Water-cooled chillers can experience flow blockages in the cooling system due to scaling or sediment buildup, which reduces cooling efficiency.
  • Pump Failures: Chillers rely on pumps to circulate water or refrigerant. A failure in these pumps can cause the entire system to overheat or shut down, requiring immediate repair.
  • Electrical Control Faults: Chillers often face control system malfunctions that can interrupt cooling performance and cause the unit to over-cycle or fail.

Air Handling Units (AHUs)

  • Filter and Coil Blockages: AHUs may develop filter or coil blockages due to dust and dirt, reducing airflow and efficiency in cooling or heating.
  • Fan and Motor Issues: Continuous use in commercial settings can cause mechanical wear on fans and motors, leading to breakdowns or noisy operation, requiring maintenance or replacement.

Daikin appliances are widely recognized for their innovation in climate control technology, providing high-efficiency solutions for both home and commercial applications. Common issues, such as refrigerant leaks, compressor failures, or airflow problems, are often addressed through regular maintenance and timely repairs. At Appliance Repair Center, we have extensive knowledge and experience in diagnosing and systematically fixing these common faults, ensuring your Daikin systems operate smoothly and efficiently.

Feel free to contact us for any assstance with your Daikin electrical appliances, both and home and commercial. We have Technicians available to serve you within and around Cape Town.